VrOne
|
ON-LINE REFERENCE DOCUMENTATION CARDINAL SYSTEMS, LLC 386-439-2525 |
Type: Interactive/Batch Application
Plots and labels a control file into the current VrOne Workspace.
Control may be plotted into the current workspace, all open workspaces or a user defined window. Options include the placement of symbols and coordinate text labels.
|
Key-in |
Description |
Range |
|
AREA= |
Area to place control |
0 = Current workspace 1 = All open workspaces 2 = Id line |
|
PLASYM= |
Place symbols? |
0=No 1=Yes |
|
LABNAM= |
Label point names? |
0=No 1=Yes |
|
LABXY= |
Label Xy coordinate? |
0=No 1=Yes |
|
LABXYO= |
Label Xy order |
0=Xy 1=Yx |
|
LABZ= |
Label elevation? |
0=No 1=Yes |
|
DECXY= |
Decimal accuracy for Xy label |
0-10 |
|
DECZ= |
Decimal accuracy for Z label |
0-10 |
|
FKEYH= |
Function key for horizontal point symbols. |
Function key name |
|
FKEYHV= |
Function key for horizontal/vertical point symbols. |
Function key name |
|
FKEYTEX= |
Function key for text labels. |
Function key name |
|
COOFIL= |
Coordinate file name to retrieve points from. |
Coordinate file name |
|
PARFIL= |
Load parameter file. |
Plot control parameter file name (.plc) |
|
RUN |
Run Plot Control. |
None |

Defines a area to plot control into. Options include the current workspace, all open workspaces or a user define line.
NOTE: Pack File (PacVr) should be done before when using options 0 and 1 to get an accurate workspace boundary
Setting this parameter to yes will place symbols.
Setting this parameter to yes will place coordinate name text labels.
Setting this parameter to yes will place coordinate North and East text labels.
Specifies the order to label the X and Y coordinates. Options are X then Y or Y then X. From a key-in the options are LabXy=0 (X then Y) or LabXy=1 (Y then X).
Setting this parameter to yes will place coordinate elevation text labels.
Defines the number of places to the right of the decimal point for North and East text labels.
Defines the number of places to the right of the decimal point for elevation text labels.
Defines the function key name to use for coordinate point symbols that represent horizontal control points.
Defines the function key name to use for coordinate point symbols that represent horizontal and vertical control points.
Defines the function key name to use for coordinate text labels.
Defines the coordinate file name to use to plot control from. The default file extension for control file is .plc.
Loads previously defined and saved plot control parameter file.
This is not a parameter but a command and runs this application.
When the Id line button is pressed on the Plot Control dialog box this menu is started and allows the identification of a polygon that defines the area to plot control within. The Area to place control (AREA=) must be set to Id line (2) for this line to be used when plotting control.
|
|
Button
|
Description |
|
1 |
Identify
line |
Identifies the line to plot control within |
|
2 |
|
|
|
3 |
|
|
|
4 |
|
|
|
5 |
|
|
|
6 |
|
|
|
7 |
|
|
|
8 |
|
|
|
9 |
|
|
|
* |
|
|
|
0 |
|
|
|
# |
End |
Abandons this menu and returns to Plot Control |